Research Careers Contact

GlossaryFunctional safety

Functional safety

Functional safety is the part of a system's overall safety that depends on electrical, electronic and software functions working correctly, including how they detect and respond to their own faults. It is governed by standards such as IEC 61508 for general electronic systems and ISO 13849 for machinery control systems.

How it works

A functional safety process starts with hazard and risk analysis: what can go wrong, how severe the harm is and how often it can occur. Each hazard that the control system must handle gets a safety function, such as stopping a motor when a guard opens or when a person enters a robot's working zone. Each safety function receives an integrity target. IEC 61508 uses safety integrity levels from SIL 1 to SIL 4, and ISO 13849 uses performance levels from PL a to PL e.

The design then has to meet that target. Requirements cover hardware architecture, such as redundant channels that cross-check each other, diagnostic coverage that measures how many dangerous faults are detected, failure rate calculations and defined responses to detected faults. Software must follow a controlled development process. The process is documented across the lifecycle, from requirements through design, testing, operation and change.

Emergency stop and safe torque off

An emergency stop circuit halts hazardous motion when a person presses a button. Its positive-opening contacts feed a two-channel safety relay or controller and stay latched until a deliberate reset. ISO 13850 sets its design principles, and IEC 60204-1 defines stop categories: category 0 removes power at once, and category 1 makes a controlled stop, then removes power. Safe torque off, or STO, defined in IEC 61800-5-2, is how a drive carries out the stop. It removes gate drive in hardware through two monitored channels while the control electronics stay powered.

Functional safety vs reliability

Reliability is about how often a system fails. Functional safety is about what happens when it does. A highly reliable system can still be unsafe if a rare failure leads to a hazard without detection. A functionally safe system can fail more often, but it detects its faults and moves to a safe state, for example by removing motor torque.

Why it matters

Robots near people and machines sold into regulated markets need safety functions designed and documented to recognized standards. Retrofitting them is hard, because they shape the architecture: which signals are redundant, which processor runs safety code and how faults are detected.

How to get it right

  • Do the hazard and risk analysis early, before choosing the architecture.
  • Keep safety functions as simple and separate from normal control as practical.
  • Use redundant channels and cross-checking where the integrity target requires them.
  • Add diagnostics such as watchdogs, memory tests and plausibility checks on sensors.
  • Analyze failure modes with FMEA and calculate failure rates for safety hardware.
  • Keep documentation and change control as strict as the design itself.

Functional safety in robotics and drone hardware

Industrial and collaborative robots use safety functions such as protective stops, safe torque off, speed and separation monitoring and safe limited speed. Mobile robots add safety-rated scanners and bumpers. Drones in regulated operations use independent flight termination and geofencing systems. In each case, hardware such as dual-channel inputs, independent watchdogs and STO circuits comes from the safety architecture.

Learn more