Research Careers Contact

GlossaryHALT vs HASS

HALT vs HASS

HALT and HASS are two accelerated stress methods used on electronics. HALT, the highly accelerated limit test, pushes a design past its specified limits to find its weak points and operating margins. HASS, highly accelerated stress screening, applies stress inside those proven margins to production units to find manufacturing defects.

How it works

HALT is run on a few prototype units during development. The units are stepped through rising cold, rising heat, fast temperature changes, multi-axis vibration and finally combined stress, while they run and are monitored. Engineers record where the unit stops working, its operating limit, and where it fails permanently, its destruct limit. Each weakness found goes through root cause analysis, is fixed, and the test repeats. IEC 62506 notes that HALT was originally spelled out as highly accelerated life test, but that it measures design limits, not life.

HASS is run on production units. Its profile is set from the HALT results, with stress high enough to expose latent defects such as weak joints or damaged parts, but low enough not to use up the life of good units. IEC 62506 defines HASS as screening for latent defects caused by manufacturing process or control errors. A related method, HASA, applies the same screen to a sample of each lot instead of every unit.

HALT vs HASS

HALTHASS
WhenDesign and developmentProduction
UnitsA few prototypesEvery unit, or a sample
StressBeyond the specification, to failureInside proven margins
GoalFind design weaknessesFind manufacturing defects

Why it matters

HALT shows how much margin a design has, quickly and before production. HASS catches defects that pass normal tests but fail early in use. A HASS profile set without HALT data risks either missing defects or damaging good units.

How to get it right

  • Run HALT early enough that design fixes are still possible.
  • Monitor units during stress, since many faults appear only while stressed.
  • Set HASS limits from HALT data, and prove the screen does not shorten the life of good units.
  • Reduce or end HASS as the process matures and the screen stops finding defects, and compare it with burn-in and ESS as options.

HALT and HASS in robotics and drone hardware

Robots and drones face vibration, shock and temperature swings that bench tests do not reproduce. HALT on motor controllers and flight controllers often finds connector, mounting and solder joint weaknesses early, and the findings feed the FMEA. HASS is used where a field failure is costly, such as on safety-related or hard-to-service units.

Learn more