GlossaryPower sequencing
Power sequencing
Power sequencing is controlling the order and timing in which a board's supply rails turn on and off. Processors, FPGAs and memory often have several rails, such as core, I/O and memory voltages, and many require them to rise and fall in a specific order within set time limits.
How it works
A typical processor uses a core rail below 1 V, an auxiliary rail, I/O rails at 1.8 V and 3.3 V and a memory rail. Its datasheet states which rails must come up first, how long to wait between them, how fast each rises and when reset can be released. Memory standards set their own rules. The JEDEC DDR4 standard, for example, defines the order in which memory supply rails ramp and when reset and clock signals start.
Sequencing is done in several ways. Simple designs chain regulators, using each one's power-good output to enable the next. Supervisor and sequencer chips watch several rails and enable them in order with programmed delays. Power management chips built for a processor handle the whole set. Digitally controlled regulators expose turn-on delays, ramp rates and fault limits over a bus such as PMBus, an open standard for power management communication.
Power-down matters too. Rails often need to fall in reverse order, and capacitors left charged on one rail feed current back into chips through another.
Power sequencing vs power-on reset
A power-on reset holds a chip in reset until its supply is stable, then releases it. Sequencing controls the order of several rails before that point. A board needs both: correct sequencing, then reset released only after every rail is in range.
Why it matters
Wrong sequencing causes some of the hardest bring-up problems: boards that start only sometimes, processors that lock up, excess current at startup and, in bad cases, damaged chips from current flowing through protection diodes into unpowered rails. These problems often depend on temperature and part tolerance, so they slip through early testing.
How to get it right
- Collect every chip's sequencing, ramp and reset requirements in one table.
- Use power-good signals, not fixed delays alone, to step through the sequence.
- Measure every rail and reset on one oscilloscope capture during bring-up.
- Test startup at temperature extremes and with slow and fast input ramps.
- Plan power-down order and discharge paths, not only power-up.
- Hold reset until every rail is in range.
Power sequencing in robotics and drone hardware
Compute modules for robot perception carry processors and memory with strict sequencing needs, often fed from batteries whose voltage sags under motor load. Brownouts during a hard maneuver have to trigger a clean, ordered shutdown and restart, not a half-powered processor. Sequencers with fault logging show what happened after a field reset.