Research Careers Contact

GlossaryIP rating

IP rating

An IP rating, or ingress protection code, is a two-digit code defined in IEC 60529 that states how well an enclosure keeps out solid objects and water. The first digit covers solids such as fingers, tools and dust. The second digit covers water, from dripping to jets to immersion. IP67, for example, means dust-tight and protected against temporary immersion.

How it works

IEC 60529 defines the test behind each digit. For solids, the first digit runs from 0, no protection, to 6, dust-tight. Lower levels use probes of set diameters, and the dust levels expose the enclosure to fine powder in a test chamber. For water, the second digit starts at 0 and climbs through dripping water, spraying at angles, splashing, water jets of increasing force, temporary immersion and continuous immersion under conditions agreed with the manufacturer, up to high-pressure, high-temperature jets. An X replaces a digit that was not tested, as in IPX4.

A rating applies to the enclosure as tested, with its seals, gaskets, cable glands and connectors in place. Water tests for other environmental conditions, such as rain or high-pressure spray, are covered by separate standards such as IEC 60068-2-18.

IP rating vs conformal coating

An IP rating describes the enclosure: it keeps water and dust away from the electronics. Conformal coating protects the board itself, as a thin film over the assembly that resists condensation, contamination and moisture that gets past the enclosure. Many outdoor products use both, since condensation forms inside sealed housings when temperature swings.

Why it matters

Buyers and operators specify IP ratings because they map to real conditions: rain, wash-down, dusty floors or puddles. A product that claims a rating has to pass the defined test, and every change to a seal, connector or vent can affect the result. A missing or weak rating limits where a robot or drone is allowed to operate.

How to get it right

  • Set the target rating from the operating environment early, since it drives connector choice, sealing and venting.
  • Choose connectors and cable glands rated to the same level as the housing, mated and unmated.
  • Add a pressure-equalizing vent to sealed housings, so temperature changes do not pump moist air past the seals.
  • Coat or pot boards that face condensation even inside a rated enclosure.
  • Test production enclosures, not only prototypes, and retest after design changes to seals or fasteners.

IP ratings in robotics and drone hardware

Outdoor drones, delivery robots and agricultural machines face rain, spray and dust. Sealing them affects thermal design, because a closed housing cannot use airflow to cool motor drivers and compute. Teams balance the rating against heat paths through the housing, and rate each external connector, including battery and charging contacts, along with the main enclosure.

Learn more