Research Careers Contact

GlossaryPCB cleaning

PCB cleaning

PCB cleaning is the removal of flux residues, handling soils and other contamination from an assembled board after soldering. Boards are cleaned in aqueous or solvent washers, or the process uses no-clean materials and skips washing.

How it works

Flux leaves residue on the board. With water-soluble flux, the residue is active and must be washed off, usually in an inline or batch washer using water or water with a saponifier, then rinsed and dried. Rosin and many no-clean residues can be removed with solvent or engineered aqueous chemistries. The cleaner has to reach under low-standoff parts such as QFNs and BGAs, where residue hides.

IPC-CH-65 gives guidelines for cleaning printed boards and assemblies, covering chemistries, equipment and cleanliness testing. J-STD-001 sets the cleanliness requirements a soldered assembly must meet, including when testing is required.

Cleaning vs no-clean

A no-clean process uses fluxes whose residues are meant to be safe if left on the board. It saves the cost and floor space of washing. The residue still has to be benign for the product's conditions, though. Under humidity and bias, some residues absorb moisture and allow leakage or corrosion. Many products that will be coated, or that run at high voltage or high humidity, are cleaned even when they use no-clean flux.

Why it matters

Residue and contamination cause leakage currents, corrosion and dendrite growth between conductors. They also keep conformal coating from adhering. These problems appear months later, as intermittent faults in humid or condensing conditions.

How to get it right

  • Decide clean or no-clean per product, based on its environment, voltage and coating plan.
  • Use a cleaning chemistry and process matched to the flux.
  • Leave enough standoff under parts for cleaning to reach.
  • Qualify the process with objective evidence, such as surface insulation resistance testing on a representative test board, since J-STD-001 does not accept ionic extraction tests alone for qualification.
  • Monitor the qualified process at intervals with ionic residue testing, as J-STD-001 describes.
  • Clean before coating unless the coating and residue are qualified together.

PCB cleaning in robotics and drone hardware

Outdoor robots and drones meet rain, dew and temperature swings. High-current motor and battery boards also run at higher voltages than logic boards. Those conditions raise the chance that residue causes leakage, so many teams clean these boards before coating them.

Learn more