Galvanic isolation

Galvanic isolation separates two circuits so no direct current can flow between them, while still passing power or signals across the barrier. It protects people and low-voltage electronics from high voltages and blocks ground currents that inject noise.

How it works

Isolation passes energy or information across an insulating barrier without a conductive path. Transformers pass power and signals magnetically. Optocouplers pass signals as light. Digital isolators use capacitive or magnetic coupling across a thin insulating layer inside the chip. Isolated DC-DC converters pass power through a small transformer.

Each isolator has ratings: the voltage it withstands briefly in testing, the working voltage it handles continuously and the surge it tolerates. IEC 60747-17 covers magnetic and capacitive coupling isolators. On the board, the isolation barrier has to be kept clear of copper on both sides by creepage and clearance distances set by IEC 60664-1 and the product's safety standard, based on voltage, pollution degree and insulation class.

Basic insulation gives one level of protection. Reinforced insulation, or double insulation, is required where a failure exposes a person to hazardous voltage.

Galvanic isolation vs a level shifter

A level shifter translates signals between voltages, such as 3.3 V and 5 V, with a shared ground. It offers no protection if one side faults to high voltage. Galvanic isolation keeps the two sides completely separate, so a fault on one side does not reach the other, and ground differences between them do not matter.

Why it matters

Isolation decides whether a fault stays contained or reaches a person or a processor. It also stops ground currents between subsystems from corrupting sensitive measurements and communication. Safety certification for products connected to mains or high-voltage batteries depends on it.

How to get it right

  • Pick isolators with working voltage and insulation class matched to the hazard.
  • Keep the barrier clear on every layer, including inner layers and under the isolator.
  • Meet creepage and clearance from the applicable standard, with margin for production variation.
  • Use isolated power for the isolated side, not a shared supply.
  • Watch for capacitance across the barrier, which couples fast transients.
  • Test isolation at production with a hipot test where safety requires it.

Galvanic isolation in robotics and drone hardware

High-voltage battery packs, motor drives and chargers on robots need isolated gate drivers, isolated current sensing and isolated communication between the power section and the control electronics. Isolated communication links, such as isolated CAN, also stop ground offsets between distant parts of a robot from corrupting data.