GlossaryHead-in-pillow
Head-in-pillow
Head-in-pillow is a BGA soldering defect where a ball rests in the melted paste on its pad but does not fuse with it. The ball and the paste each melt during reflow, but they stay as two separate masses, like a head resting on a pillow.
How it works
During reflow, the BGA package and the board both warp as they heat. If the package corner lifts away from the board at peak temperature, some balls separate from their paste. The ball and the paste each melt, and their surfaces oxidize while apart. As the board cools and the package flattens, the ball drops back onto the paste, but the oxide layers keep them from joining. The two harden with a seam between them.
IPC-7095 describes head-in-pillow and its causes in its BGA process guidance. Causes include package and board warpage, too little paste, weak flux activity, oxidized balls and profiles with too long a soak.
Head-in-pillow vs open joint
A plain open joint has no contact between ball and pad. Head-in-pillow has contact but no metal bond. That makes it harder to find. The joint passes electrical test because the ball touches the paste, then fails later under vibration or temperature change.
Why it matters
Head-in-pillow joints often pass in-circuit and functional test and then fail in the field. On X-ray, the ball looks seated, so it takes angled views, cross sections or careful image review to see the seam. It is one of the more costly BGA defects because it escapes test.
How to get it right
- Use enough paste on BGA pads, and check volume at paste inspection.
- Use a paste with strong flux activity and good oxidation resistance.
- Shorten long soaks that exhaust flux before peak.
- Consider nitrogen reflow to limit oxidation.
- Store BGAs dry and within shelf life to avoid oxidized balls.
- Use angled X-ray on first articles and when changing paste or profile.
Head-in-pillow in robotics and drone hardware
Processor and FPGA BGAs on robot controllers and flight computers carry the main logic, and they see vibration in use. A head-in-pillow joint there passes bench test and then fails on a moving machine, which makes the fault hard to trace.