Single-pair Ethernet, or SPE, is a family of Ethernet standards that carry data over one twisted pair of wires instead of the two or four pairs used in standard office Ethernet. It brings Ethernet to sensors, actuators and controllers with lighter, cheaper cables and connectors.

How it works

IEEE 802.3bw, published in 2015, defined 100BASE-T1, which carries 100 Mbit/s over one twisted pair for about 15 m, first aimed at vehicles. Later standards added 1000BASE-T1 for gigabit speeds, 802.3cg, published in 2019, for 10 Mbit/s, and 802.3dg, published in 2026, which defines 100BASE-T1L for 100 Mbit/s over long single-pair runs.

802.3cg defines two physical layers. 10BASE-T1L reaches up to 1 km on 18 AWG cable at 10 Mbit/s, full duplex, for long runs in industrial plants. 10BASE-T1S reaches about 15 m point to point and supports a multidrop mode with several nodes sharing one pair over about 25 m, similar in topology to CAN.

Power over Data Lines, or PoDL, sends power on the same pair as data, so one two-wire cable powers and connects a device. Because SPE is Ethernet, it uses the same frames, addressing and software stack as other Ethernet links, and switches bridge it to standard Ethernet.

Single-pair Ethernet vs CAN bus

CAN bus is simple, robust and widely used in vehicles and robots, with data rates up to 1 Mbit/s for classic CAN and higher for CAN FD. It uses its own message format and needs gateways to reach IP networks. SPE carries standard Ethernet traffic at 10 Mbit/s and above, so devices join an IP network directly, at the cost of more complex transceivers and software.

Why it matters

Robots and vehicles have many sensors and controllers spread across their structure. Wiring each with four-pair Ethernet adds weight and bulk, while field buses need gateways and separate software. SPE gives one network type from cloud to sensor over light two-wire cabling.

How to get it right

  • Pick the physical layer by distance, speed and topology: 10BASE-T1L or 100BASE-T1L for long runs, T1S for short multidrop buses, 100BASE-T1 or 1000BASE-T1 for higher data rates.
  • Use cable and connectors rated for single-pair Ethernet and the required data rate.
  • Follow the transceiver maker's layout for the pair, magnetics or capacitive coupling and protection.
  • Protect connectors from surges and static.
  • Budget PoDL power, including cable loss over the full length.